Basic Info.
Certification
RoHS, CCC, ISO9001, CE
Heat Source Type
Air Source Heat Pump
Power Supply
400V/3pH/50Hz, 60Hz as Option
Product Description
Withair® Modular Air-Cooled Heat Pump Unit is a very intelligent heat pump system with flexible capacity output. It could adjust heating capacity output automatically according to requirements. It is much more energy-saving with a long lifespan.
Withair® Modular Air-Cooled Heat Pump Unit is a kind of central air conditioner which adopts air as the cooling & heating source and water as cooling & heating medium. With rich experience in R&D, design and application, Withair® constantly lanuched new environment-friendly modular units, which improves the structures, systems and programs based on original products, and designs special series of comfortable and technological units. The environment-friendly modular unit has complete functions and various specifications, with basic modules of any combination available for different models. Withair® offer quiet, reliable, energy efficient equipment. These units incorporate high quality compressors, state-of-the-art coil design, and innovative packaging. As a sort of integrated equipment, it needs no cooling tower, cooling water pump, boiler and corresponding auxiliary parts, which makes the system more simple, saves installation space, convenient maintenance and energy saving, thus it is very suitable for areas that are short of water. several modules can be formed in to a air-cooled heat pump module unit by connecting each module's inlet & outlet pipeline in parallel. with a system without cooling water, with simple pipelines, moderate cost, short construction period, allowing staged investment, the whole unit consists of 1~16 modules and the maximum capacity is 9,040kW.
Withair® Modular Air-Cooled Heat Pump Unit can be widely applied to civilian projects and industrial projects, such as hotel, villa, restaurant, hospital, factory, etc. it is a wise choice for areas where water is insufficient or there are strict limits on noise level and surroundings. Each unit is verified for total unit performance before shipping to insure quality standards are inherent in every unit.
Unit adopts modular design, relatively independent modules units can be any combination and through microcomputer for centralized control, unit according to the change of load start-stop corresponding number of module unit to adjust the supply of cold (heat) capacity, to achieve the goal of high efficiency and energy saving. Units can effectively under the climatic conditions of heating at -20ºC and heat unit during normal operation the system is 3 times more than ordinary electric heater, winter climate is relatively low and no boiler or other heating conditions particularly applicable areas. with FCU, VAV and AHU and fresh air units, semi-central air conditioning system has the flexible layout, beautiful shape, saving space, convenient adjustment, low running noise, etc.
-- Specifications (ON/OFF Version , Cooling & Heating & EVI Operating Conditions) --Model No. | W01R1-72E | W01R1-72E x 2 | W01R1-72E x 3 | W01R1-72E x 4 | W01R1-72E x 5 | W01R1-72E x 6 |
Cooling condition | Cooling capacity | kW | 72 | 142 | 216 | 288 | 360 | 432 |
US.RT | 20 | 40 | 60 | 80 | 100 | 120 |
EER | kW/kW | 3.35 | 3.35 | 3.35 | 3.35 | 3.35 | 3.35 |
Input power | kW | 21.5 | 43.0 | 64.5 | 86.0 | 107.5 | 129.0 |
Heating condition | Heating capacity | kW | 76 | 152 | 228 | 304 | 380 | 456 |
US.RT | 21.6 | 43.2 | 64.8 | 86.4 | 108 | 129.6 |
COP | kW/kW | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 |
Input power | kW | 20.7 | 41.4 | 62.1 | 82.8 | 103.5 | 124.2 |
EVI condition Super-low ambient | Heating capacity | kW | 52 | 96 | 144 | 192 | 240 | 288 |
US.RT | 14.8 | 29.6 | 44.4 | 59.2 | 74.0 | 88.8 |
COP | kW/kW | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 |
Input power | kW | 19.2 | 38.4 | 57.6 | 76.8 | 96 | 115.2 |
Power supply | | 380V/3P/50Hz (400V/415V/3P/50Hz, 230V/380V/460V/3P/60Hz as option) |
Compressor | Type | | Advanced fully hermetic scroll compressor (EVI -enhanced vapor injection) , Inverter compressor as option |
Safe protection device | High/low pressure switch, overload protection, counter clock wise and short phase protection (power phases sequence protection),lack water(water-flow switch),anti-freezing protection, etc. |
Air side heat exchanger | Type | | High efficiency exchanger copper tube and aluminum fin coil |
Air flow volume | m³/h | 2.6 x 104 | 5.2 x 104 | 7.8 x 104 | 10.4 x 104 | 13 x 104 | 15.6 x 104 |
Water side heat exchanger | Type | | High efficiency shell-and-tube heat exchanger or tube in tube heat exchanger |
Water flow volume | m³/h | 11.7 | 23.4 | 35.1 | 46.8 | 58.5 | 70.2 |
Water pressure drop | kPa | ≤40 | ≤40 | ≤60 | ≤60 | ≤60 | ≤60 |
Max. working pressure | MPa | 1.0 |
Entering/leaving water pipe | inch | 2-1/2" | 2-1/2" | 2-1/2" | 2-1/2" | 2-1/2" | 2-1/2" |
Installation water pipe | inch | 3" | 4" | 4" | 4" | 4" | 4" |
Dimension | Length | mm | 2060 | 2060 | 2060 | 2060 | 2060 | 2060 |
Width | mm | 1030 | 1030+n | 1030+2n | 1030+3n | 1030+4n | 1030+5n |
Height | mm | 1890 | 1890 | 1890 | 1890 | 1890 | 1890 |
Noise level | dB(A) | 65 | 67 | 69 | 72 | 75 | 78 |
Water proof level | | IPX4 |
Electric shock protection | | I |
Refrigerant | Type | | HFC- R410A or R407C |
Charging rate | kg | 9.5 x 2 | 9.5 x 4 | 9.5 x 6 | 9.5 x 8 | 9.5 x 10 | 9.5 x 12 |
Unit weight | kg | 820 | 1640 | 2460 | 3280 | 4100 | 4920 |
User's choice(auxiliary electric heater) | kW | 20 | 40 | 60 | 80 | 100 | 120 |
Control type | | Wired control, manual or automatic start up, the running status display and malfunction alarm, etc. |
Model No. | W01R1-105E | W01R1-105E x 2 | W01R1-105E x 3 | W01R1-105E x 4 | W01R1-105E x 5 | W01R1-105E x 6 |
Cooling condition | Cooling capacity | kW | 105 | 210 | 315 | 420 | 525 | 630 |
US.RT | 30 | 60 | 90 | 120 | 150 | 180 |
EER | kW/kW | 3.36 | 3.36 | 3.36 | 3.36 | 3.36 | 3.36 |
Input power | kW | 31.2 | 62.4 | 93.6 | 124.8 | 156.0 | 187.2 |
Heating condition | Heating capacity | kW | 112 | 234 | 351 | 468 | 585 | 702 |
US.RT | 32.0 | 64.0 | 96.0 | 128.0 | 160.0 | 192.0 |
COP | kW/kW | 3.36 | 3.36 | 3.36 | 3.36 | 3.36 | 3.36 |
Input power | kW | 33.3 | 66.6 | 99.9 | 133.2 | 166.5 | 199.8 |
EVI condition Super-low ambient | Heating capacity | kW | 75 | 150 | 225 | 300 | 375 | 450 |
US.RT | 21.3 | 42.6 | 63.9 | 85.2 | 106.5 | 127.8 |
COP | kW/kW | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 |
Input power | kW | 27.7 | 55.4 | 83.1 | 110.8 | 138.5 | 166.2 |
Power supply | | 380V/3P/50Hz (400V/415V/3P/50Hz, 230V/380V/460V/3P/60Hz as option) |
Compressor | Type | | Advanced fully hermetic scroll compressor (EVI -enhanced vapor injection) |
Safe protection device | High/low pressure switch, overload protection, counter clock wise and short phase protection (power phases sequence protection),lack water(water-flow switch),anti-freezing protection, etc. |
Air side heat exchanger | Type | | High efficiency exchanger copper tube and aluminum fin coil |
Air flow volume | m³/h | 3.6 x 104 | 7.2 x 104 | 10.8 x 104 | 14.4 x 104 | 18 x 104 | 21.6 x 104 |
Water side heat exchanger | Type | | High efficiency shell-and-tube heat exchanger or tube in tube heat exchanger |
Water flow volume | m³/h | 16.2 | 32.4 | 48.6 | 64.8 | 81.0 | 97.2 |
Water pressure drop | kPa | ≤40 | ≤40 | ≤60 | ≤60 | ≤60 | ≤60 |
Max. working pressure | MPa | 1.0 |
Entering/leaving water pipe | inch | 2-1/2" | 2-1/2" | 2-1/2" | 2-1/2" | 2-1/2" | 2-1/2" |
Installation water pipe | inch | 3 | 4 | 4 | 4 | 4 | 5 |
Dimension | Length | mm | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 |
Width | mm | 1030 | 1030+n | 1030+2n | 1030+3n | 1030+4n | 1030+5n |
Height | mm | 2062 | 2062 | 2062 | 2062 | 2062 | 2062 |
Noise level | dB(A) | 65 | 67 | 69 | 72 | 75 | 78 |
Water proof level | | IPX4 |
Electric shock protection | | I |
Refrigerant | Type | | HFC- R410A or R407C |
Charging rate | kg | 13 x 2 | 13 x 4 | 13 x 6 | 13 x 8 | 13 x 10 | 13 x 12 |
Unit weight | kg | 1050 | 2100 | 3150 | 4200 | 5100 | 6150 |
User's choice(auxiliary electric heater) | kW | 30 | 60 | 90 | 120 | 150 | 180 |
Control type | | Wired control, manual or automatic start up, the running status display and malfunction alarm, etc. |
Model No. | W01R1-140E | W01R1-140E x 2 | W01R1-140E x 3 | W01R1-140E x 4 | W01R1-140E x 5 | W01R1-140E x 6 |
Cooling condition | Cooling capacity | kW | 140 | 280 | 420 | 560 | 700 | 840 |
US.RT | 40 | 80 | 120 | 160 | 200 | 240 |
EER | kW/kW | 3.33 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 |
Input power | kW | 42.0 | 84.0 | 126.0 | 168.0 | 210.0 | 252.0 |
Heating condition | Heating capacity | kW | 156 | 312 | 468 | 560 | 700 | 840 |
US.RT | 44 | 88 | 132 | 176 | 220 | 264 |
COP | kW/kW | 3.58 | 3.29 | 3.29 | 3.29 | 3.29 | 3.29 |
Input power | kW | 43.5 | 87.0 | 130.5 | 174.0 | 217.5 | 261.0 |
EVI condition Super-low ambient | Heating capacity | kW | 100 | 200 | 300 | 400 | 500 | 600 |
US.RT | 29 | 58 | 87 | 116 | 145 | 174 |
COP | kW/kW | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 |
Input power | kW | 38.4 | 76.8 | 115.2 | 153.6 | 192 | 230.4 |
Power supply | | 380V/3P/50Hz (400V/415V/3P/50Hz, 230V/380V/460V/3P/60Hz as option) |
Compressor | Type | | Advanced fully hermetic scroll compressor (EVI -enhanced vapor injection) |
Safe protection device | High/low pressure switch, overload protection, counter clock wise and short phase protection (power phases sequence protection),lack water(water-flow switch),anti-freezing protection, etc. |
Air side heat exchanger | Type | | High efficiency exchanger copper tube and aluminum fin coil |
Air flow volume | m³/h | 5.2 x 104 | 10.4 x 104 | 15.6 x 104 | 20.8 x 104 | 26 x 104 | 31.2 x 104 |
Water side heat exchanger | Type | | High efficiency shell-and-tube heat exchanger or tube in tube heat exchanger |
Water flow volume | m³/h | 23.4 | 46.8 | 70.2 | 93.6 | 117 | 140.4 |
Water pressure drop | kPa | ≤60 | ≤60 | ≤70 | ≤70 | ≤75 | ≤80 |
Max. working pressure | MPa | 1.0 |
Entering/leaving water pipe | inch | 3" | 3" | 3" | 3" | 3" | 3" |
Installation water pipe | inch | 4" | 4" | 4" | 4" | 4" | 4" |
Dimension | Length | mm | 2400 | 2400 | 2400 | 2400 | 2400 | 2400 |
Width | mm | 1915 | 1915+n | 1915+2n | 1915+3n | 1915+4n | 1915+5n |
Height | mm | 2080 | 2080 | 2080 | 2080 | 2080 | 2080 |
Noise level | dB(A) | 71 | 72 | 74 | 76 | 78 | 81 |
Water proof level | | IPX4 |
Electric shock protection | | I |
Refrigerant | Type | | HFC- R410A or R407C |
Charging rate | kg | 9.5 x 4 | 9.5 x 8 | 9.5 x 12 | 9.5 x 16 | 9.5 x 20 | 9.5 x 24 |
Unit weight | kg | 1450 | 2900 | 4350 | 5800 | 7250 | 8700 |
User's choice(auxiliary electric heater) | kW | 40 | 80 | 120 | 160 | 200 | 240 |
Control type | | Wired control, manual or automatic start up, the running status display and malfunction alarm, etc. |
Notes: 1. Nominal cooling operating conditions: entering chilled water temperature 12ºC, leaving temperature 7ºC; outdoor dry bulb temperature 35ºC,wet bulb temperature 24ºC. Nominal heating operating conditions: entering hot water temperature 40ºC,leaving temperature 45ºC; outdoor dry bulb temperature 7ºC,wet bulb temperature 6ºC; Nominal heating water operating conditions: entering hot water temperature 15ºC,leaving temperature 55ºC; dry bulb temperature 20ºC,wet bulb temperature 15ºC. Nominal EVI heating operating conditions: entering hot water temperature 36ºC,leaving temperature 41ºC; dry bulb temperature -12ºC,wet bulb temperature -14ºC.2. The controllers need to ordered separately, including wire controller, communication line, IOM, temperature sensor and water flow switch.3. These parameter were tested according to pure water, not include anti-freezing liquid and water pump power.4. Chiller unit without heating parameters.5. In actual use, the cooling/heating loss should be considered after the installation of the system piping, pumps, valve, dirt, etc. about 6%.6. For other working conditions or capacity parameters, please contact Withair for cooling ambient condition under 5ºC.
7. There will be no further notice if the parameters changes due to product optimization.
8. The units of the same model or different models can be combined freely. Each system can combine up to 16 modules.
9. Manufacturer reserves the right to make changes to above specifications without prior notice, please refer to the factory configuration when purchasing.
Address:
Xidi Second Block, Wanda Plaza, Northwest Corner of The Intersection of Jiangdong Road and Jiqingmen Street, Jianye District, Nanjing, Jiangsu, China
Business Type:
Manufacturer/Factory
Business Range:
Construction & Decoration, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001
Company Introduction:
Withair® Is a global provider & the premium manufacturer in sustainable energy solutions supplying HVACR products & services for heating, cooling, hot water, indoor air quality, industrial refrigeration, and heat recovery that reflect today′s demand for sustainable construction, comfortable indoor climate and industrial cooling & heating process application.
Withair® Specialises in innovative custom highly-configurable products designed to meet the your needs. We insure products are designed for long life by using highest quality materials, for all controls, safety, and components we only use top world-wide recognized brands. All products are rigorously tested before leaving us, going through many stages of quality control before being shipped.
At Withair® , our aim is to support the growth, profit, and sustainability goals of our clients by delivering innovative solutions with n X value. We gain a deep understanding of our client′s needs and business objectives first and foremost by gaining and leveraging our technical knowledge, innovative thinking, and vast equipment resources. From heating & cooling solutions and air quality management, to energy performance and efficiency determination, Withair® Delivers the results.
Withair® Products & solutions combine utmost efficiency with minimum energy consumption and strict respect of the environment, the idea proved to be
A winning one in just a few years, Withair® Became the leader in the sector!
Withair® Has highly effective professional team to service customers
Known for their professionalism and personal integrity, Withair′s highly skilled engineers, technicians, electricians, stable manufacturing workers, strict quality controller, and quick-reaction & professional after-service staff utilize their multi-disciplinary expertise in the creation and production of every solution.
Close cooperation among Withair′s design, production and service teams - who are located under one roof and linked by advanced computerized systems - enables the Company to supply the widest possible range of products - from single units to very large quantities - while assuring rapid delivery and competitive pricing.